吴立锋1,彭 珍2,杨善让3
(1.华北科技学院 电子信息工程系,北京 101601;2.华北科技学院 计算机系,北京 101601;3.东北电力大学 节能与测控技术研究中心,吉林吉林 132012)
摘要:利用热平衡理论和流体力学的知识推导的污垢热阻软测量模型,以及设计的污垢热阻在线监测装置,对监测到的污垢热阻时间序列的数据进行Logistic拟合、多项式拟合和S函数拟合的比较,得到了换热管的污垢热阻随时间变化的数学模型,并从理论上对此模型进行了探讨,验证了此模型的正确性。
关键词:软测量;污垢热阻;时间序列
Online Fouling Monitoring Technique Based on Softsensor Technology
WU Li-feng1,PENG Zhen2,YANG Shan-rang3
(1.Department of Electricity and Information,North China Institute of Science and Technology,Beijing 101601, China;2.Dept.of Computer,North China Institute of Science and Technology,Beijing 101601, China;3.Energy Conservation and Measure-Control Technique Research Center of NortheastInstitute of Electric Power Engineering,Jilin 132012,China)
Abstract:This paper deduced a soft sensor mode on fouling thermal resistance by using the thermal balance theory and fluid mechanics and designed an on-line monitoring device of fouling thermal resistance.Three functional models (Logistic,polynomial and S function model) were combined and compared in fitting the fouling thermal resistance based on the data series derived from monitoring device,so a mathematic mode that the variations of fouling thermal resistance of the transfer tube with the time was obtained.In the end,the model was theoretically discussed and demonstrated.
Key words:soft-sensor technology; fouling thermal resistance; time series |